SIMPLE TO INSTALL:
■ Capability to install the UPS into any distribution system(neutral not required on rectifier input);
■ Capability to separate the rectifier/bypass power networks and to power them from two separate sources, without Galvanic
isolation (Necessary on UPS without an output transformer).
ADVANCE COMMUNICATION:
■ Compatible with TeleNetGuard for remote maintenance;
■ Advanced, multi-platform communication for all operation systems and network environments: Watch & Save 3000 monitoring
and shut-down software included, with SNMP agent, for Windows 2008, Vista,2003, XP; Mac OS X, Linux, Novel l and
most popular Unix operatingsystems;
■ The UPS is supplied with a cable for direct connection to the PC(Plug and Play);
■ RS232 double Serial port;Installation slot for an Emergency Power Off (EPO) interface to al low the UPS to be switched off
remotely in an emergency;
■ Generator interface: enables desynchronisation of the UPS output from a generator supply which may be subject to phase and
frequency variations. The interface also enables more economic use of the battery charge.
CNG330 150KVA | ||||||||||||
Input | ||||||||||||
Rated voltage | 400 Vac three-phase | |||||||||||
Voltage range | 380/400/415VAC(+25%,Can be set through the LCD panel) | |||||||||||
Frequency range | 40-70Hz(Automatically select synchronization range according to grid frequency) | |||||||||||
Range(HZ) | 50±5%(±10%)Bypass synchronization tracking | |||||||||||
Battery voltage(VDC) | 384 | |||||||||||
Output | ||||||||||||
Power factor | 0.8/0.9 | |||||||||||
Voltage(V) | L-N: 220±1% L-L: 380±1% | |||||||||||
Waveform distortion | Linear loadTHD<3%; Nonlinear loadTHD<5% | |||||||||||
Overload capacity | 125% full load for 10 minutes, maintain 150 % full load for 1 minute and then switch to bypass power supply, after reducing the load can automatically restore the inverter | |||||||||||
Others | ||||||||||||
Panel display | LED displays working status and fault indication; LCD displays three-phase input voltage, input frequency, three-phase output voltage, load ,battery voltage, battery charge and discharge current, etc | |||||||||||
Display | LCD 7" touch screen display | |||||||||||
Alarm function | Battery low voltage, abnormal power supply, overload, UPS failure, over temperature protection | |||||||||||
Protection | Input over voltage, battery under voltage, overload, short circuit, over temperature protection | |||||||||||
Cooling way | Forced cooling |