Add to Cart
100Ah(16S) Lithium-Ion Battery Pack
Description and Model:
This product is a new type of backup power supply for the development of high-tech products,
can be widely used in indoor distribution stations, integrated base stations, marginal stations, ETC,
distributed power supply and other fields.
Adopted by the high safety performance, lithium battery cathode material for lithium iron phosphate,
high safety, high stability, high cycle life, high specific energy, specific power, low temperature performance
is superior, but large current charge and discharge.
The battery management system (BMS), with the charge, over discharge, short circuit, over-current (load),
temperature, flow, total pressure protection,charging under the secondary electricity, balanced and various
protective functions, providing the bluetooth , CAN ,RS485 communication interface and the upper machine
to realize remote monitoring, can be connected to the base station power environmental monitoring systems,
Intelligent software anti-theft design.
Standard design, suitable for installation in 19-inch standard cabinet, low operating environment requirements
(can be in -20 ~ 60℃, humidity < 95% normal work), small size light weight, easy installation, simple maintenance
in the later stage, can save considerable upfront investment and maintenance costs in the later stage.Ensure the
life of lithium battery and reduce the daily maintenance work.
Manufacturing standard reference:
Key features:
1. Lithium ferrous phosphate battery(LiFePO4), high safety, high energy density, excellent cycling
performance;
2. BMS, battery management system, with the intelligent positive protection functions;
3. Automatic charge and discharge management;
4. Alarm function, when the battery voltage is lower than the alarm value or too low, it will automatically
power down to protect the battery;
5. The battery pack has good electromagnetic compatibility.
Basic Characteristics Reference:
No. | Item | Specification |
1 | Watt Hour | 5120Wh |
2 | Operating voltage range | 40V~58.4V |
3 | Standard charging/discharging method | 50A |
4 | Maximum continuous charging/discharging current | 100A |
5 | Cycle Life | ≥3000 cycles (0.5C charge , 0.5C discharge) 80%DOD |
6 | Operating Temperature | -20℃-60℃ |
7 | Storage Temperature | -20℃~50℃ |
8 | Shipment voltage | ≥48V |
9 | Charge retention and capacity recovery capability | Standard charge the battery, and then put aside at room temperature for 28d or 55 ℃ for 7d, Charge retention rate ≥90%, Recovery rate of charge≥90 |
Safe Characteristic:
No. | Item | Testing instruction | Requirement |
1 | Over-charge test | Charge in accordance with the following two ways (Choosing one between the two). (1)Charge at 1C current for 90min or until voltage of some single battery reaches 5.0V (stop test when fulfills either condition). (2)Charge at 3C current until the voltage of some single battery reaches 10.0V, then stop the test. | The battery shall not explode or catch fire. |
2 | Over-discharge test | Charge the battery. Place at 20±5℃ for 1h, then discharge in 1/3C current at same temperature until so cell’s voltage is 0V. | The battery shall not explode or catch fire. |
3 | Short-circuiting Test | After charge batteries, place at 20±5℃ for 1h. Short the battery for 10min, the external circuit resistance should be less than 5mΩ. | The battery shall not explode or catch fire. |
Safety characteristics test no electronic protection circuit;
86Kpa-106Kpa ;Above technical performance standard test environment temperature: 20±5℃;
Relative humidity: 65 ± 20% (unless otherwise requested), Atmospheric pressure: 86Kpa-106Kpa.
Shipment package:
No fall down, no pile up over 8 layers, and keep face up.
Storage conditions:
ventilated place, charge 1h for every 3 months.
materials and be away from fire and heat.